Categories | Elisa Test Kit |
---|---|
Brand Name: | BIOVANTION |
Model Number: | TY0031 |
Certification: | ISO 13485 |
Place of Origin: | CHINA |
MOQ: | 1000 Box |
Price: | discussible |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 100000 Box/carton |
Delivery Time: | 2-7 days |
Packaging Details: | carton/box |
Delivery: | Within 48 hours |
Packaging Specifications: | 8 x 12 strips, 96 wells |
Country Of Origin: | China,BeiJing |
Detection Limit: | 18 months |
Storage: | 2-8℃ |
Specimen: | Whole blood |
Assification: | class1 |
Product Type: | Elisa Test Kit |
Detection Kit for Estradial (E2)(ELISA).It is used in quantitative tests for Estradial in human serum.
Product details | Description |
Delivery | Within 48 hours |
Packaging Specifications | 8 x 12 strips, 96 wells |
Country Of Origin | China |
Manufacturer | 18 months |
Preservation method | 2℃-8℃ |
Specimen | Whole blood |
Assification | class1 |
Type | Elisa Test Kit |
E2 kit is based on competitive method. Coat micro well plates with E2 antibody. Add E2 calibrator (or patient sample) and HRP-E2 to form E2-antibody—HRP-E2 complex. The binding amount of HRP-E2 is reversely proportional to E2 content in serum. Remove the unbound E2-HRP. Add substrate and detect absorbent value. Calculate E2 content of patient serum through computer or plotting fitting
concentration-absorbent value curve.
Coated Microplate: 1 plate (8×12 wells), Ready to use. Coated with anti-T4 antibody and sealed in an aluminum bag. Remove the strips in the resealable bag with a desiccant to protect from moisture after opened. Store at 2~8℃ until expiration date.
1. Allow all specimens and reagents to reach room temperature
(~25°C) and mix thoroughly by gentle inversion before use.
2.Prepare Wash Buffer by diluting Wash Concentrate 20-fold with
deionized water. The diluted wash solution is stable in room
temperature for at least one week.
1. Do not exchange reagents from different lots or use reagents
from other commercially available kits. The components of the kit
are precisely matched for optimal performance of the tests.
2. Specimens with Hyperlipidemia and icterus show no effects on the
detection results. But specimen with severe hemolysis will affect
the color of the result, other test methods are suggested to use.
3. Allow the reagents and specimens to reach room temperature
before use. Shake reagent gently before use.
4. Concentrated washing liquid will produce crystal at room
temperature, should be diluted completely before use.
5. Never reuse microplate sealing membrane.
6. Samples containing anti-sperm antibody, anti-endometrial
antibody will not affect the results.
7. Each component of the kit was inactivated, however, it should be
regarded as potentially infectious.
1. Handling should preclude any pipetting by mouth. Use only
pipettes with disposable tips for each specimen.
2.Do not mix materials from different master lots. Do not use kit
components beyond the expiration date.
3.All materials should be brought to room temperature before use.
![]() |