IP66 Protection Degree Explosion Proof Gas Detector Sensor For Hazardous Environments,Average Operating Current <30mA

Categories Gas Detector Sensor
Brand Name: Kacise
Model Number: TDLAS103
Place of Origin: China (Mainland)
Certification: certificate of explosion-proof, CE
MOQ: 1pcs
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Delivery Time: 5-8 working days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Detection mode: Dispersive
Products dimensions: φ41.7mmx63.6mm
Explosion proof sign: Ex Ia IICT6 Ga
Average operating current: <30mA
Product weight: 255g
Peak current: <210mA
Response time: T90<15s
Operating temperature: -40℃~ +70℃
Protection degree: IP66
  • Product Details
  • Company Profile

IP66 Protection Degree Explosion Proof Gas Detector Sensor For Hazardous Environments,Average Operating Current <30mA

Introduction


This 3.3V methane sensor, developed using TD-LAS technology, leverages a 1653.7nm laser to detect methane based on its characteristic absorption spectrum. It is immune to interference from water vapor and other gases. The sensor combines direct and wavelength modulation absorption techniques with an "N" type optical design, providing a long optical path and superior sensitivity. Low-temperature laser and photodetector devices are used along with a temperature compensation algorithm to ensure strong environmental adaptability. With its standard thread installation interface and communication protocol, it’s highly versatile. It’s used as the core part of methane gas monitors for spaces like underground areas, restaurants, industrial sites, and coal mines.


Feature

High detection accuracy

Direct and wavelength modulation technology combined with folded optical path design, measurement error ≤±6% true value @25℃

Good environmental adaptability

Wide temperature compensation correction algorithm, can meet -40~+70℃ application

Strong anti-interference

Methane "fingerprint spectrum" laser absorption detection technology, anti-poisoning, anti-water vapor and other gas interference;

Strong structural protection

Stainless steel material design, meets the explosion-proof level Exia IIC T6 Ga

Low cost

Long service life, low power consumption, modular design, easy to integrate


Dimensions


Technical Parameters:

ParametersTechnical Indicators
Measuring gasMethane
Measuring principleTD-LAS
Detection modeDispersive
Measuring range0-20% VOL (customizable)
Measurement error @25℃<+0.06%VOL,0-1%VOL
<+6%True value,1-20% VOL
Lower detection limit0.2% VOL
Minimum resolution0.01% VOL
Response timeT90<15s
Operating voltage3.0VDC ~3.6VDC
Average operating current<30mA
Peak current<210mA
Output modeStandard TTL serial port
Operating temperature-40℃~ +70℃
Operating humidity0 ~ 99% RH (condensation)
Explosion proof signEx ia IICT6 Ga
Intrinsic safety parameterUi:3.3V Ii:50mA
Pi:0.250W Ci:20uF
Li:3.14uH
Protection degreeIP66
Product weight255g
Products dimensionsφ41.7mmx63.6mm

Applications:

a) The sensor continuously outputs the measured methane concentration, measured temperature, measured pressure, laser signal strength, laser operating temperature and fault code through the standard TTL serial port

b) It has a self-test function, which can detect whether the laser, photoelectric detector and voltage stabilization sensor are normal, which helps to eliminate the fault point.


Communication Interface and Definition

Interface form: SH1.0mm/4P

Cable length: 200mm

NumberColorInterface definition
1RedVCC
2BlackGND
3BlueRX
4GreenTX

Communication Protocol

(1) Communication interface configuration

UART serial port: Baud rate: 115200, data bits: 8 bits,

Stop bit: 1 bit, parity bit: no check

(2) Description of communication protocol

Byte sequence numberFunction codeByte numberUnitExample
0Head of frame1-A
1-7Concentration7%VOL+000.00
8Blank space1-<SP>
9-13Ambient temperature5+23.7
14Blank space1-<SP>
15-21Ambient air pressure7hPa1006.22
22Blank space1-<SP>
23-27Intensity of light5-+16.1
28Blank space1-<SP>
29-35Gain coefficient7-B+6.0
36Blank space1-<SP>
37-38Fault code2-00
39Blank space1-<SP>
40-41Xor check code2-3D
42Carriage return character1<CR>:<CR>:
43Line break character1<LF><LF>

After the sensor is powered on, it goes through a period of preprocessing (6-10s) and then begins to periodically (1Hz) output a fixed-length string. The string format is shown in the figure above.


Output string parsing (sample):

A 000.00 + 24.0 + 1006.22 + 16.1 + 006.0 B 00 13

A: the frame head;

+000.00: methane concentration value, two decimal places reserved, unit %vol;

+ 24.0: the environment temperature, the unit ℃;

1006.22: the environment pressure, the unit hPa;

16.1: the laser light intensity and effective range 3.6 21.6;

006.0: magnification factor, normal range 1.0-126.0;

00: fault codes

01: abnormal optical signal; 02; Ambient temperature or abnormal pressure; Optical signal is too strong; 04 laser temperature anomaly;

05: light signal is too weak;

13: xor check code


Fault Code

Fault codeMeaningFault codeMeaning
0Sensor working properly3The laser signal is strong
1The photodetector signal is abnormal4Laser temperature anomaly
2Temperature and pressure sensor abnormal5The laser signal is too weak

Precautions

a) The working voltage of the sensor is 3.3V, and the serial interface level is 3.3V;

b) sensor contains precision optical components, please avoid violent collision;

c) Working environment conditions: -40℃ ~ +70℃

d) Relative humidity 0-99% RH (non-condensation).


Note: The working voltage of the sensor is 3.3V. It is forbidden to connect the power supply voltage exceeding 3.6VDC to the sensor to avoid damage to the sensor.


Support and Services

We provide technical support for Gas Detector Sensors, including expert help for resolving issues and troubleshooting, as well as repair and maintenance services. Our calibration and testing services ensure accuracy, and we offer product documentation and manuals. We also assist in product selection and customization, aiming to provide the best support to keep your detectors working efficiently.


Packing and Shipping:
Product Packaging:
Gas Detector Sensor unit
User manual
Mounting hardware
Calibration certificate
Shipping Information:
Expected delivery time: 5-8 business days

Cheap IP66 Protection Degree Explosion Proof Gas Detector Sensor For Hazardous Environments,Average Operating Current <30mA for sale
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
Company Info
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly